Documentation home

Primeros pasos con SharKNX

El asistente de SharKNXProyectos ETS en SharKNXKNX Data SecureKNX IP SecureEl concepto Shark Hunt

Cómo usar alias y scripts del asistenteCómo conectarse a un Gateway KNXCómo crear una Shark HuntCómo exportar telegramasCómo inspeccionar los objetos de comunicación de un dispositivoCómo cargar un proyecto ETSCómo programar la dirección física de un dispositivoCómo leer la tabla de filtros de un acopladorCómo escanear una línea de bus KNXCómo enviar comandos KNXCómo configurar KNX Data SecureCómo configurar KNX IP SecureCómo usar el asistente

Conexiones del proyectoPágina ConectarPágina DiagnósticoPágina MonitorPágina ProjectPágina SettingsPágina Shark HuntsPágina Asistente

Comandos del asistenteFormato de archivo de alias y scriptsFormatos de ExportaciónPreguntas FrecuentesLímitesMenú lateral y AccionesSintaxis de filtros del monitorReferencia de ajustesPlanes de SuscripciónTipos de Datapoints Compatibles (DPTs)
Guía de la app

Conexiones del proyecto

Mira cómo se enlazan los dispositivos KNX de tu proyecto ETS a través de las direcciones de grupo: emisores, receptores y rutas del pulsador al actuador, en tu teléfono.

En esta página
  1. Opening the page
  2. Searching
  3. Device mode: who is this device linked to?
  4. Group address mode: who is on this group address?
  5. How SharKNX works out the roles
  6. What it's useful for
  7. Related

The Project Connections page - titled Connections in the app - shows how the devices in your ETS project talk to each other through group addresses. It is not the same as the Connect page, where you connect to a gateway: this page works entirely from your project. Pick a device to see which devices it controls and which control it, or pick a group address to see who sends on it and who listens. It answers in seconds what usually takes a laptop and ETS: what is this push button actually wired to?

The page works from your loaded ETS project, so it needs no gateway connection - you can use it anywhere, even before you arrive on site.


Opening the page

  • ⋯ Actions → Connections - available once an ETS project is loaded.
  • A device's sheet on the Project page (Devices, Topology, or Buildings tab) - opens the page for that device.
  • A group address's sheet on the Project page - tap Connections to open the page for that group address.

Searching

At the top of the page, choose what you want to look up:

Mode Enter Shows
Device An individual address, e.g. 1.1.5, or part of a device name The devices this device is linked to
Group address A group address, e.g. 1/2/3, or part of its name Every device on that group address and its role

Tap Show, or the arrow in the search field, to see the result. The icon at the left of the search field opens Browse, a list to pick from; Clear results at the top right starts over. Addresses must match exactly - 1.1.1 never finds 1.1.10 - while names can match partly. If more than one device or group address matches a name, SharKNX lets you Browse the matches and pick one.


Device mode: who is this device linked to?

The result groups every linked device by direction:

Section Means
Send to Devices this device sends to - for a push button, the actuators it switches
Receive from Devices this device listens to - for an actuator, the push buttons and sensors that control it
Bidirectional Devices it both sends to and receives from on the same group addresses

Each linked device shows its name, individual address, and how many group addresses connect the two.

Project Connections in device mode for 1.1.1, with Send to and Receive from sections listing linked devices

Following a connection path

Tap a linked device to see exactly how the two are connected. The sheet shows both devices and lists every group address they share. Expand one to see its datapoint type and the communication object on each side - the path a telegram takes, for example from object 257 on 1.1.1 through 0/0/2 to object 2 on 1.1.230. A Send row lets you write to or read that group address straight away.

Connection path between 1.1.1 and 1.1.230, with group address 0/0/2 expanded to show the objects on both devices and a Send row

Group address mode: who is on this group address?

The result lists every device linked to the group address, grouped by role:

Section Means
Senders Devices that transmit on it - push buttons, sensors, logic
Receivers Devices that react to it - actuators, displays
Bidirectional Devices that both send and receive, such as actuators reporting their state
Unknown Devices whose direction the project doesn't make clear

Expand a device to see which of its communication objects are linked to the group address. The Send button above the result lets you write to or read the group address directly - no need to find it on the Project page first.

Project Connections in group address mode for 0/2/1, with the Send button, one sender, and two bidirectional devices

How SharKNX works out the roles

Roles come from the communication object flags in your ETS project. An object with the transmit (T) or read-on-init (I) flag is a sender; one with the write (W) flag is a receiver; one with both T and W is bidirectional. An object that only answers reads (R) counts as a sender, since it puts values on the bus. The page shows what ETS says should happen - to check what a physical device is actually programmed with, read it with Tools → Inspect.

If a device or group address has no connections, SharKNX tells you: the device may have no communication objects assigned, or the group address may not be linked to any object in ETS.


What it's useful for

  • Troubleshooting - a light doesn't switch? Look up the push button, follow the path to the actuator, and check the group address in between. Then send to it from the same page.
  • Before changing something - look up a group address to see every device that will react if you write to it.
  • Understanding a project you didn't create - start from any device and follow its links through the installation.
  • Commissioning checks - confirm that every push button reaches the actuators it should, before you walk the building.
  • Planning a test - find all receivers of a group address, then build a Shark Hunt that switches it and monitors their responses.

With no ETS project, you can still see a single device's links by reading its memory on Tools → Inspect - see Inspect a Device.


Related

  • ETS Projects in SharKNX - everything a loaded project unlocks
  • Project Page - browse and filter the whole installation
  • Send Commands - all the ways to send
AnteriorCómo usar el asistenteSiguientePágina Conectar

En esta página

  1. Opening the page
  2. Searching
  3. Device mode: who is this device linked to?
  4. Group address mode: who is on this group address?
  5. How SharKNX works out the roles
  6. What it's useful for
  7. Related

← SharKNX product page

logo

Solutions

  • Services
  • Products
  • HaaS

Company

  • About Us
  • Contact

Legal

  • Privacy Policy
  • Cookie Policy
  • Terms & Conditions

Contact

  • info@owl-automata.com
  • Athens, Greece

© 2026 OWL-Automata.com. All rights reserved OWL Automata

  • Terms & Conditions
  • Privacy Policy
  • Cookie Policy