Reference

Supported Datapoint Types (DPTs)

The KNX Datapoint Types SharKNX supports for decoding and composing telegrams, covering both ETS project import and manual command entry.

  • English
  • ·Deutsch
  • ·Français
  • ·Español
  • ·Italiano

SharKNX supports KNX Datapoint Types in two contexts:

  • Decoding - values decoded and displayed when receiving telegrams in the Monitor. Applies to all DPTs in this document.
  • Sending - DPTs available for selection when composing a command. A subset of the decodable DPTs. Marked with ✅ in the table below.

If a telegram arrives for a group address whose DPT is unknown or not yet supported, the raw hex payload is shown instead of a decoded value.


Overview

DPT Name Size Send
1 1-bit Boolean 1 bit ✅
2 1-bit Controlled 2 bits ✅
3 3-bit Controlled (Step) 4 bits ✅
4 Character 1 byte ✅
5 8-bit Unsigned Value 1 byte ✅
6 8-bit Signed Value 1 byte ✅
7 2-byte Unsigned Value 2 bytes ✅
8 2-byte Signed Value 2 bytes ✅
9 2-byte Float 2 bytes ✅
10 Time of Day 3 bytes ✅
11 Date 3 bytes ✅
12 4-byte Unsigned Value 4 bytes ✅
13 4-byte Signed Value 4 bytes ✅
14 4-byte IEEE 754 Float 4 bytes ✅
15 Entrance Access 4 bytes -
16 14-Character String 14 bytes ✅
17 Scene Number 1 byte ✅
18 Scene Control 1 byte ✅
19 Date & Time 8 bytes ✅
20 1-byte Enum 1 byte ✅
21 8-bit Status / Flags 1 byte ✅
22 16-bit Status / Flags 2 bytes ✅
23 2-bit Set 1 byte -
24 Variable String (ISO 8859-1) variable -
25 Double Nibble 1 byte -
26 Scene Info 1 byte -
27 32-bit Combined Info 4 bytes -
28 Variable String (UTF-8) variable ✅
29 8-byte Signed Value 8 bytes ✅
30 Channel Activation (24 ch) 3 bytes -
206 Time Delay + HVAC Mode 3 bytes -
217 Version 2 bytes -
219 Alarm Info 6 bytes -
222 Temperature Setpoints (×3) 6 bytes -
225 Scaling Step Time 4 bytes -
229 Metering Value 6 bytes -
232 RGB Colour 3 bytes ✅
234 Language Code 2 bytes -
235 Tariff Active Energy 6 bytes -
240 Combined Position (blinds) 3 bytes -
241 Shutter Actuator Status 4 bytes -
242 CIE xyY Colour 6 bytes ✅
243 xyY Colour Transition 8 bytes -
249 Brightness & CCT Transition 6 bytes ✅
250 Brightness & CCT Control (relative) 3 bytes ✅
251 RGBW Colour 6 bytes ✅
252 Relative Control RGBW 5 bytes ✅
253 Relative Control xyY 4 bytes -
254 Relative Control RGB 3 bytes ✅
275 Four 2-byte Floats 8 bytes -

Subtypes

The following sections list the subtypes selectable when sending commands, grouped by main type. DPTs with a single subtype or no send support are omitted.

DPT 1 - 1-bit Boolean

Subtype Description
1.001 Switch (Off / On)
1.002 Boolean
1.003 Enable
1.004 Ramp
1.005 Alarm
1.006 Binary Value
1.007 Step
1.008 Up / Down
1.009 Open / Close
1.010 Start / Stop
1.011 State
1.012 Invert
1.013 Dim Send Style
1.014 Input Source
1.015 Reset
1.016 Acknowledge
1.017 Trigger
1.018 Occupancy
1.019 Window / Door
1.021 Logical Function
1.022 Scene A/B
1.023 Shutter / Blinds Mode
1.100 Cooling / Heating

DPT 2 - 1-bit Controlled

Subtype Description
2.001 Switch Control
2.002 Boolean Control
2.003 Enable Control
2.004 Ramp Control
2.005 Alarm Control
2.006 Binary Value Control
2.007 Step Control
2.008 Direction Control 1
2.009 Direction Control 2
2.010 Start Control
2.011 State Control
2.012 Invert Control

DPT 3 - 3-bit Controlled

Subtype Description
3.007 Dimming Control
3.008 Blind Control

DPT 4 - Character

Subtype Description
4.001 Character (ASCII)
4.002 Character (ISO 8859-1)

DPT 5 - 8-bit Unsigned

Subtype Description Range Unit
5.001 Scaling / Percentage 0–100 %
5.003 Angle 0–360 °
5.004 Percentage 0–255 %
5.005 Ratio 0–255 -
5.006 Tariff 0–255 -
5.010 Counter Pulses 0–255 -

DPT 6 - 8-bit Signed

Subtype Description Range Unit
6.001 Percentage −128–127 %
6.010 Counter Pulses −128–127 -

DPT 7 - 2-byte Unsigned

Subtype Description Unit
7.001 Pulses -
7.002 Time Period ms
7.003 Time Period 10 ms
7.004 Time Period 100 ms
7.005 Time Period s
7.006 Time Period min
7.007 Time Period h
7.011 Length mm
7.012 Current mA
7.013 Brightness lux
7.600 Colour Temperature K

DPT 8 - 2-byte Signed

Subtype Description Unit
8.001 Pulses Difference -
8.002 Time Lag ms
8.003 Time Lag 10 ms
8.004 Time Lag 100 ms
8.005 Time Lag s
8.006 Time Lag min
8.007 Time Lag h
8.010 Percentage Difference %
8.011 Rotation Angle °

DPT 9 - 2-byte Float

Subtype Description Unit
9.001 Temperature °C
9.002 Temperature Difference K
9.003 Temperature Change K/h
9.004 Illuminance lux
9.005 Wind Speed m/s
9.006 Pressure Pa
9.007 Humidity %
9.008 Air Quality (CO₂) ppm
9.009 Air Flow m³/h
9.010 Time s
9.011 Time ms
9.020 Voltage mV
9.021 Current mA
9.022 Power Density W/m²
9.023 Kelvin per Percent K/%
9.024 Power kW
9.025 Volume Flow l/h
9.026 Rain Amount l/m²
9.027 Temperature °F
9.028 Wind Speed km/h

DPT 13 - 4-byte Signed

Subtype Description Unit
13.001 Counter Pulses -
13.002 Flow Rate m³/h
13.010 Active Energy Wh
13.011 Apparent Energy VAh
13.012 Reactive Energy VARh
13.013 Active Energy kWh
13.014 Apparent Energy kVAh
13.015 Reactive Energy kVARh
13.100 Time Lag s

DPT 14 - 4-byte IEEE Float (selected subtypes)

Only a subset of DPT 14's 80 subtypes are available in the send UI. All subtypes are decoded in the monitor.

Subtype Description Unit
14.007 Angle °
14.019 Electric Current A
14.027 Electric Potential V
14.033 Frequency Hz
14.056 Power W
14.065 Speed m/s
14.068 Temperature °C
14.069 Temperature Absolute K
14.070 Temperature Difference K

DPT 16 - 14-Character String

Subtype Description
16.000 ASCII
16.001 ISO 8859-1

DPT 20 - 1-byte Enum

Subtype Description
20.002 Building Mode
20.003 Occupied Mode
20.004 Priority
20.005 Light Application Mode
20.006 Light Application Area
20.007 Alarm Class Type
20.008 PSU Mode
20.013 Time Delay
20.014 Wind Force (Beaufort)
20.100 Fuel Type
20.101 Burner Type
20.102 HVAC Mode
20.103 DHW Mode
20.104 Load Priority
20.105 HVAC Control Mode
20.106 HVAC Emergency Mode
20.107 Changeover Mode
20.108 Valve Mode
20.109 Damper Mode
20.110 Heater Mode
20.111 Fan Mode
20.112 Master / Slave Mode
20.113 Status Room Setpoint

Note: Display of enum labels for most DPT 20 subtypes falls back to the raw mode number. Named labels (e.g. "Comfort", "Standby") are shown for 20.102 (HVAC Mode) and a few others.

DPT 21 - 8-bit Status Flags

Subtype Description
21.001 General Status
21.002 Device Control
21.100 Forcing Signal
21.102 Room Heating Controller Status
21.103 Solar DHW Controller Status
21.105 Room Cooling Controller Status
21.106 Ventilation Controller Status

DPT 22 - 16-bit Status Flags

Subtype Description
22.100 DHW Controller Status
22.101 RHCC Status

DPT 29 - 8-byte Signed (64-bit Energy)

Subtype Description Unit
29.010 Active Energy Wh
29.011 Apparent Energy VAh
29.012 Reactive Energy VARh

DPT 232 / 242 / 249 / 250 / 251 / 252 / 254 - Colour & Lighting

DPT Description Size
232.600 RGB Colour 3 bytes
242.600 CIE xyY Colour 6 bytes
249.600 Brightness & Colour Temperature Transition 6 bytes
250.600 Brightness & Colour Temperature Control (relative) 3 bytes
251.600 RGBW Colour 6 bytes
252.600 Relative Control RGBW 5 bytes
254.600 Relative Control RGB 3 bytes

Decode-only DPTs

The following DPTs are decoded in the monitor when the ETS project provides the DPT assignment, but are not available for manual command composition in the send UI.

DPT Description
15.000 Entrance Access (access code)
23.x 2-bit Action Set (on/off, up/down, alarm)
24.x Variable-length String (ISO 8859-1)
25.x Double Nibble
26.001 Scene Info
27.001 Bit-combined Info On/Off
30.1010 Channel Activation (24 channels)
206.x Time Delay + HVAC/DHW/Occupancy/Building Mode
217.001 DPT Version
219.001 Alarm Info
222.x Room Temperature Setpoints (×3)
225.x Scaling Step Time
229.001 Metering Value
234.001 Language Code (ISO 639-1)
235.001 Tariff Active Energy
240.800 Combined Position (blinds/shutter)
241.800 Shutter Actuator Status
243.x xyY Colour Transition
253.x Relative Control xyY
275.x Four 2-byte Floats

← SharKNX

logo

Solutions

  • Services
  • Products
  • HaaS

Company

  • About Us
  • Contact

Legal

  • Privacy Policy
  • Cookie Policy
  • Terms & Conditions

Contact

  • info@owl-automata.com
  • Athens, Greece

© 2026 OWL-Automata.com. All rights reserved OWL Automata

  • Terms & Conditions
  • Privacy Policy
  • Cookie Policy